Journal cover Journal topic
Atmospheric Chemistry and Physics An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 5.509 IF 5.509
  • IF 5-year value: 5.689 IF 5-year 5.689
  • CiteScore value: 5.44 CiteScore 5.44
  • SNIP value: 1.519 SNIP 1.519
  • SJR value: 3.032 SJR 3.032
  • IPP value: 5.37 IPP 5.37
  • h5-index value: 86 h5-index 86
  • Scimago H index value: 161 Scimago H index 161
Volume 9, issue 8 | Copyright
Atmos. Chem. Phys., 9, 2635-2645, 2009
https://doi.org/10.5194/acp-9-2635-2009
© Author(s) 2009. This work is distributed under
the Creative Commons Attribution 3.0 License.

  16 Apr 2009

16 Apr 2009

Intercomparison of ammonia measurement techniques at an intensively managed grassland site (Oensingen, Switzerland)

M. Norman1,*, C. Spirig2, V. Wolff3, I. Trebs3, C. Flechard2,**, A. Wisthaler1, R. Schnitzhofer1, A. Hansel1, and A. Neftel2 M. Norman et al.
  • 1Institute for Ion Physics and Applied Physics, University of Innsbruck, Innsbruck, Austria
  • 2Agroscope Reckenholz Tänikon Research Station (ART), Zürich, Switzerland
  • 3Max Planck Institute for Chemistry, Biogeochemistry Department, Mainz, Germany
  • *now at: Environment and Health Administration, Stockholm City, Sweden
  • **now at: Institut National de la Recherche Agronomique (INRA), Rennes, France

Abstract. As part of a field campaign in the framework of the NitroEurope project, three different instruments for atmospheric ammonia (NH3) measurements were operated side-by-side on a managed grassland site in Switzerland: a modified Proton Transfer Reaction Mass Spectrometer (PTR-MS), a GRadient of AErosol and Gases Online Registrator (GRAEGOR), and an Automated Ammonia Analyzer (AiRRmonia). The modified PTR-MS approach is based on chemical ionization of NH3 using O2+ instead of H3O+ as ionizing agent, GRAEGOR and AiRRmonia measure NH4+ in liquids after absorption of gaseous NH3 in a rotating wet-annular denuder and through a gas permeable membrane, respectively. Bivariate regression slopes using uncorrected data from all three instruments ranged from 0.78 to 0.97 while measuring ambient NH3 levels between 2 and 25 ppbv during a 5 days intercomparison period. Correlation coefficients r2 were in the range of 0.79 to 0.94 for hourly average mixing ratios. Observed discrepancies could be partly attributed to temperature effects on the GRAEGOR calibration. Bivariate regression slopes using corrected data were >0.92 with offsets ranging from 0.22 to 0.58 ppbv. The intercomparison demonstrated the potential of PTR-MS to resolve short-time NH3 fluctuations which could not be measured by the two other slow-response instruments. During conditions favoring condensation in inlet lines, the PTR-MS underestimated NH3 mixing ratios, underlining the importance of careful inlet designs as an essential component for any inlet-based instrument.