Journal cover Journal topic
Atmospheric Chemistry and Physics An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 5.509 IF 5.509
  • IF 5-year value: 5.689 IF 5-year 5.689
  • CiteScore value: 5.44 CiteScore 5.44
  • SNIP value: 1.519 SNIP 1.519
  • SJR value: 3.032 SJR 3.032
  • IPP value: 5.37 IPP 5.37
  • h5-index value: 86 h5-index 86
  • Scimago H index value: 161 Scimago H index 161
Volume 7, issue 18
Atmos. Chem. Phys., 7, 4905-4934, 2007
https://doi.org/10.5194/acp-7-4905-2007
© Author(s) 2007. This work is licensed under
the Creative Commons Attribution-NonCommercial-ShareAlike 2.5 License.

Special issue: MIPAS (Michelson Interferometer for Passive Atmosphere Sounding):...

Atmos. Chem. Phys., 7, 4905-4934, 2007
https://doi.org/10.5194/acp-7-4905-2007
© Author(s) 2007. This work is licensed under
the Creative Commons Attribution-NonCommercial-ShareAlike 2.5 License.

  21 Sep 2007

21 Sep 2007

Validation of MIPAS HNO3 operational data

D. Y. Wang2,1, M. Höpfner1, C. E. Blom1, W. E. Ward2, H. Fischer1, T. Blumenstock1, F. Hase1, C. Keim1, G. Y. Liu1, S. Mikuteit1, H. Oelhaf1, G. Wetzel1, U. Cortesi3, F. Mencaraglia3, G. Bianchini3, G. Redaelli4, M. Pirre5, V. Catoire5, N. Huret5, C. Vigouroux6, M. De Mazière6, E. Mahieu7, P. Demoulin7, S. Wood8, D. Smale8, N. Jones9, H. Nakajima10, T. Sugita10, J. Urban11, D. Murtagh11, C. D. Boone12, P. F. Bernath13,12, K. A. Walker14,12, J. Kuttippurath16,15, A. Kleinböhl15,18, G. Toon18, and C. Piccolo19 D. Y. Wang et al.
  • 1Institut für Meteorologie und Klimaforschung (IMK),Forschungszentrum Karlsruhe und Universität Karlsruhe, Karlsruhe, Germany
  • 2Physics Department, University of New Brunswick, Fredericton, New Brunswick, Canada
  • 3Istituto di Fisica Applicata "N.~Carrara" (IFAC) del Consiglio Nazionale delle Ricerche (CNR), Firenze, Italy
  • 4Dipartimento di Fisica,CETEMPS, Universita' di L'Aquila, L'Aquila, Italy
  • 5Laboratoire de Physique et Chimie de l'Environnement, Université d'Orléans (LPCE-CNRS), Orléans, France
  • 6Belgian Institute for Space Aeronomy (BIRA-IASB), Brussels, Belgium
  • 7Institut d'Astrophysique et de Géophysique, University of Liège (ULg), Liège, Belgium
  • 8National Institute for Water and Atmospheric Research (NIWA), Lauder, Otago, New Zealand
  • 9University of Wollongong, Wollongong, Australia
  • 10National Institute for Environmental Studies, Tsukuba, Japan
  • 11Department of Radio and Space Science, Chalmers University of Technology, Göteborg, Sweden
  • 12Department of Chemistry, University of Waterloo, Waterloo, Ontario, Canada
  • 13Department of Chemistry, University of York, Heslington, York, UK
  • 14Department of Physics, University of Toronto, Toronto, Canada
  • 15Institute of Environmental Physics, University of Bremen, Bremen, Germany
  • 16CNRS/LMD Ecole Polytechnique, Palaiseau Cedex, France
  • 18Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
  • 19Department of Physics, Oxford University, Oxford, UK

Abstract. Nitric acid (HNO3) is one of the key products that are operationally retrieved by the European Space Agency (ESA) from the emission spectra measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) onboard ENVISAT. The product version 4.61/4.62 for the observation period between July 2002 and March 2004 is validated by comparisons with a number of independent observations from ground-based stations, aircraft/balloon campaigns, and satellites. Individual HNO3 profiles of the ESA MIPAS level-2 product show good agreement with those of MIPAS-B and MIPAS-STR (the balloon and aircraft version of MIPAS, respectively), and the balloon-borne infrared spectrometers MkIV and SPIRALE, mostly matching the reference data within the combined instrument error bars. In most cases differences between the correlative measurement pairs are less than 1 ppbv (5–10%) throughout the entire altitude range up to about 38 km (~6 hPa), and below 0.5 ppbv (15–20% or more) above 30 km (~17 hPa). However, differences up to 4 ppbv compared to MkIV have been found at high latitudes in December 2002 in the presence of polar stratospheric clouds. The degree of consistency is further largely affected by the temporal and spatial coincidence, and differences of 2 ppbv may be observed between 22 and 26 km (~50 and 30 hPa) at high latitudes near the vortex boundary, due to large horizontal inhomogeneity of HNO3. Similar features are also observed in the mean differences of the MIPAS ESA HNO3 VMRs with respect to the ground-based FTIR measurements at five stations, aircraft-based SAFIRE-A and ASUR, and the balloon campaign IBEX. The mean relative differences between the MIPAS and FTIR HNO3 partial columns are within ±2%, comparable to the MIPAS systematic error of ~2%. For the vertical profiles, the biases between the MIPAS and FTIR data are generally below 10% in the altitudes of 10 to 30 km. The MIPAS and SAFIRE HNO3 data generally match within their total error bars for the mid and high latitude flights, despite the larger atmospheric inhomogeneities that characterize the measurement scenario at higher latitudes. The MIPAS and ASUR comparison reveals generally good agreements better than 10–13% at 20–34 km. The MIPAS and IBEX measurements agree reasonably well (mean relative differences within ±15%) between 17 and 32 km. Statistical comparisons of the MIPAS profiles correlated with those of Odin/SMR, ILAS-II, and ACE-FTS generally show good consistency. The mean differences averaged over individual latitude bands or all bands are within the combined instrument errors, and generally within 1, 0.5, and 0.3 ppbv between 10 and 40 km (~260 and 4.5 hPa) for Odin/SMR, ILAS-II, and ACE-FTS, respectively. The standard deviations of the differences are between 1 to 2 ppbv. The standard deviations for the satellite comparisons and for almost all other comparisons are generally larger than the estimated measurement uncertainty. This is associated with the temporal and spatial coincidence error and the horizontal smoothing error which are not taken into account in our error budget. Both errors become large when the spatial variability of the target molecule is high.

Publications Copernicus
Special issue
Download
Citation
Share