Journal cover Journal topic
Atmospheric Chemistry and Physics An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 5.509 IF 5.509
  • IF 5-year value: 5.689 IF 5-year 5.689
  • CiteScore value: 5.44 CiteScore 5.44
  • SNIP value: 1.519 SNIP 1.519
  • SJR value: 3.032 SJR 3.032
  • IPP value: 5.37 IPP 5.37
  • h5-index value: 86 h5-index 86
  • Scimago H index value: 161 Scimago H index 161
Volume 6, issue 9
Atmos. Chem. Phys., 6, 2401-2410, 2006
https://doi.org/10.5194/acp-6-2401-2006
© Author(s) 2006. This work is licensed under
the Creative Commons Attribution-NonCommercial-ShareAlike 2.5 License.
Atmos. Chem. Phys., 6, 2401-2410, 2006
https://doi.org/10.5194/acp-6-2401-2006
© Author(s) 2006. This work is licensed under
the Creative Commons Attribution-NonCommercial-ShareAlike 2.5 License.

  29 Jun 2006

29 Jun 2006

In-situ comparison of the NOy instruments flown in MOZAIC and SPURT

H.-W. Pätz1, A. Volz-Thomas1, M. I. Hegglin2, D. Brunner2, H. Fischer3, and U. Schmidt4 H.-W. Pätz et al.
  • 1Institut für Chemie und Dynamik der Geosphäre II: Troposphäre, Forschungszentrum Jülich, Germany
  • 2Institute for Atmospheric and Climate Science, ETH-Zürich, Switzerland
  • 3Max Planck Institute for Chemistry, Mainz, Germany
  • 4Institut für Atmosphäre und Umwelt, Johann Wolfgang Goethe-Universität, Frankfurt, Germany

Abstract. Two aircraft instruments for the measurement of total odd nitrogen (NOy) were compared side by side aboard a Learjet A35 in April 2003 during a campaign of the AFO2000 project SPURT (Spurengastransport in der Tropopausenregion). The instruments albeit employing the same measurement principle (gold converter and chemiluminescence) had different inlet configurations. The ECO-Physics instrument operated by ETH-Zürich in SPURT had the gold converter mounted outside the aircraft, whereas the instrument operated by FZ-Jülich in the European project MOZAIC III (Measurements of ozone, water vapour, carbon monoxide and nitrogen oxides aboard Airbus A340 in-service aircraft) employed a Rosemount probe with 80 cm of FEP-tubing connecting the inlet to the gold converter. The NOy concentrations during the flight ranged between 0.3 and 3 ppb. The two data sets were compared in a blind fashion and each team followed its normal operating procedures. On average, the measurements agreed within 7%, i.e. within the combined uncertainty of the two instruments. This puts an upper limit on potential losses of HNO3 in the Rosemount inlet of the MOZAIC instrument. Larger transient deviations were observed during periods after calibrations and when the aircraft entered the stratosphere. The time lag of the MOZAIC instrument observed in these instances is in accordance with the time constant of the MOZAIC inlet line determined in the laboratory for HNO3.