Articles | Volume 20, issue 13
https://doi.org/10.5194/acp-20-7941-2020
https://doi.org/10.5194/acp-20-7941-2020
Research article
 | 
08 Jul 2020
Research article |  | 08 Jul 2020

An investigation on hygroscopic properties of 15 black carbon (BC)-containing particles from different carbon sources: roles of organic and inorganic components

Minli Wang, Yiqun Chen, Heyun Fu, Xiaolei Qu, Bengang Li, Shu Tao, and Dongqiang Zhu
Abstract

The hygroscopic behavior of black carbon (BC)-containing particles (BCPs) has a significant impact on global and regional climate change. However, the mechanism and factors controlling the hygroscopicity of BCPs from different carbon sources are not well understood. Here, we systematically measured the equilibrium and kinetics of water uptake by 15 different BCPs (10 herb-derived BCPs, 2 wood-derived BCPs, and 3 soot-type BCPs) using a gravimetric water vapor sorption method combined with in situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). In the gravimetric analysis, the sorption–desorption equilibrium isotherms were measured under continuous-stepwise water vapor pressure conditions, while the kinetics was measured at a variety of humidity levels obtained by different saturated aqueous salt solutions. The equilibrium water uptake of the tested group of BCPs at high relative humidity (>80 %) positively correlated to the dissolved mineral content (0.01–13.0 wt %) (R2=0.86, P=0.0001), the content of the thermogravimetrically analyzed organic carbon (OCTGA, 4.48–15.25 wt %) (R2=0.52, P=0.002), and the content of the alkali-extracted organic carbon (OCAE, 0.14–8.39 wt %) (R2=0.80, P=0.0001). In contrast, no positive correlation was obtained with the content of total organic carbon or elemental carbon. Among the major soluble ionic constituents, chloride and ammonium were each correlated with the equilibrium water uptake at high relative humidity. Compared with the herbal BCPs and soot, the woody BCPs had much lower equilibrium water uptake, especially at high relative humidity, likely due to the very low dissolved mineral content and OC content. The DRIFTS analysis provided generally consistent results at low relative humidity. The kinetics of water uptake (measured by pseudo-second-order rate constant) correlated to the content of OCTGA and OCAE as well as the content of chloride and ammonium at low relative humidity (33 %) but to the porosity of BCPs at high relative humidity (94 %). This was the first study to show that BCPs of different types and sources had greatly varying hygroscopic properties.

Dates
1 Introduction

Black carbon (BC) refers to a collective term of refractory and insoluble aggregates of small carbon spherules generated from incomplete combustion of biomass and fossil fuels (Bond et al., 2013). BC-containing particles (BCPs) are ubiquitous in the atmosphere and are a major component of atmospheric carbonaceous aerosols (Schwarz et al., 2008). Due to the strong ability to absorb visible light (Yuan et al., 2016), BCPs cause positive radiative forcing effects on climate and are considered an important factor driving global warming (Matthews et al., 2009). Once immersed into cloud droplets, BCPs can also facilitate water evaporation and cloud dispersion via enhanced absorption of solar radiation and thus produce indirect radiative forcing effects (Powelson et al., 2014). Additionally, the large specific surface area of BCPs creates a potential for heterogeneous reactions with trace gases (such as volatile halocarbons) in the atmosphere (Qiu et al., 2012), thus heavily impacting atmospheric chemistry and air quality. Hygroscopicity is a key determinant of physical, chemical, and optical properties of BCPs by changing particle size, phase state, and quality and morphological development, which in turn affect aerosol radiation effect, formation of cloud and ice nuclei, and heterogeneous chemical reactions (Bond et al., 2013; Liu et al., 2018). Furthermore, the hygroscopicity of BCPs is an important factor contributing to the risk of human respiratory infections, cardiovascular diseases, and other infectious diseases (Haddrell et al., 2015).

Inherited from a parent carbon source or produced from combustion process, a large content of inorganic impurities are often present in BCPs, consisting of a variety of amorphous or crystalline salts (sulfates, chlorides, etc.) as well as semicrystalline minerals (such as silica) (Stanislav et al., 2013). Despite the relatively low content, the inorganic components in BCPs play a significant role in water uptake, depending on their types, contents, and mixing ratios (Lewis et al., 2009). As the factors and processes governing the hygroscopic deliquescence of inorganic salts are very complicated(Reid et al., 2005; Zhang et al., 2012), it is a great challenge to assess the contribution of a specific salt to the overall hygroscopicity of BCPs, and thus its role is still controversial. Previous studies suggested that KCl was responsible for the high hygroscopicity of BCPs produced by fresh biomass burning (Posfai et al., 2003), while the presence of K2SO4 or KNO3 caused the low hygroscopicity of BCPs produced by aged biomass burning (Li et al., 2003).

The organic components in BCPs consist of graphitized elemental carbon (EC) and non-condensed, amorphous organic carbon (OC) (Lian and Xing, 2017). The contribution of EC to the overall hygroscopicity of BCPs is considered low due to the very high hydrophobicity (Seisel et al., 2005). The role of OC in the hygroscopic growth of BCPs is intricate and debatable. The positive effect of OC is mainly attributed to water absorption by the oxygen-containing functional groups (Fletcher et al., 2007; Suda et al., 2014). The negative effect of OC is suggested to stem from the impeded mass transfer process of water molecules by formation of coatings on hygroscopic minerals or inhomogeneous morphology inside the particle (Sjogren et al., 2007; Stemmler et al., 2008). In addition to the total content, the molecular weight, water solubility, surface tension, and type and content of functional groups of OC were all found to influence the overall hygroscopicity of BCPs. Moreover, the effect of OC on BCP hygroscopicity is further complicated by the formation of organic minerals (presumably through strong covalent bonds) (Archanjo et al., 2014; Reid et al., 2005; Zuend et al., 2011).

The carbon sources for BCPs released into the atmosphere are expected to be highly diversified and cover a wide range of plant biomass, coals, and refined oil products, although their quota can hardly be accurately assessed (Andreae and Gelencser, 2006). The chemical compositional, structural, and morphological properties of BCPs depend significantly on carbon sources and combustion conditions (Xiao et al., 2018). For instance, crop-residue-derived biochar often has higher mineral content than wood-derived charcoal, while biochar formed at higher pyrolysis temperatures generally have higher aromaticity, specific surface area, and pore volume but lower polarity than biochar formed at lower temperatures (Wei et al., 2019). Compared with char and charcoal, soot (another type of BCPs) produced from fossil fuel combustion is comprised of more regular shaped, chain-like agglomerates of primary particles, which consist of perturbed graphitic layers oriented concentrically in an onion-like fashion (Nienow and Roberts, 2006). Previous studies on hygroscopicity of BCPs have mainly focused on wood-derived BCPs (Carrico et al., 2010; Day et al., 2006), whereas BCPs from other carbon sources have been largely overlooked. It remains unclear whether BCPs from different carbon sources would differ significantly in hygroscopicity.

Herein we systematically investigated the equilibrium and kinetics of water uptake by 15 different BCPs derived from wood, herb, coal, and diesel at varying relative humidity (RH) levels by gravimetric sorption and in situ diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). The chemical, compositional, and structural properties of the tested group of BCPs were thoroughly characterized to unveil the key factors controlling the hygroscopic properties.

2 Experimental methods

2.1 Preparation of BCPs

A total of 15 BCPs were tested, including 10 herb-derived BCPs, 2 wood-derived BCPs, and three soot-type BCPs. The herbs used for preparation of herbal BCPs were amaranth, peanuts, pea, grass, rice, wheat, corn, millet, sorghum (Nantong, Jiangsu Province, China), and bamboo (Lishui, Zhejiang Province, China), and the wood used for preparation of woody BCPs were red pine and poplar (Lishui, Zhejiang Province, China). The dried and dehydrated biomass was pulverized into a fine powder using a high-speed pulverizer (FW 100, Tianjin Taisite Instrument Co., China) and pyrolyzed in a muffle furnace under oxygen-limited conditions. The oven temperature was programmed to increase from 20 to 400 C in 2 h and maintained at 400 C for 3 h. The Weifu diesel soot was purchased from Wuxi Weifu Automotive Diesel System Co., Ltd. (Jiangsu Province, China). According to the information provided by the manufacturer, the soot was produced under laboratory conditions by burning diesel (Diesel #5, China) at 1000 C and was collected by a diesel particulate filter (NGK-6000YE) from the exhaust stream at a carbon deposition temperature of 250 C. The diesel engine soot was collected in outdoor conditions from the freshly discharged exhaust particles on the tailpipe of a diesel truck (Dongfeng, CY4100, 2015, China) equipped with a diesel engine (CY4100Q, 3.7 L, Diesel #0) and a diesel particulate filter (BST-5L-QCD). The household soot was collected on the inner wall of a stove chamber (Linkou County, Heilongjiang Province, China) 1 h later after burning of coal and wood for winter cooking and heating under limited oxygen exposure. The obtained samples of BCPs were further ground to pass a 100-mesh sieve (0.15 mm) and stored sealed in a brown glass bottle at 4 C.

2.2 Characterization of BCPs

Elemental analysis (EA) was performed using a Vario micro cube elemental analyzer (Elementar, Hanau, Germany). Surface elemental compositions were measured by X-ray photoelectron spectroscopy (XPS) (PHI 5000 VersaProbe, UlVAC-PHI, Japan). Mineral compositions were measured by X-ray fluorescence (XRF) (ARL-9800, ARL Corporation, Switzerland). Fourier-transform infrared (FTIR) spectra were recorded on a Bruker Tensor 27 Karlsruhe spectrometer (Germany) using KBr pellets in the range of 400 to 4000 cm−1. X-ray diffraction (XRD) spectra were recorded on an AXS D8 Advance spectrometer (Germany) using Cu Kα radiation at a 2θ angle ranging from 5 to 70. Raman spectra were collected on a Horiba Jobin Yvon LabRam HR-800 spectrometer equipped with a 514 nm laser (France). N2 adsorption isotherms to the 15 BCPs were obtained on a Micrometrics ASAP 2020 (Micromeritics Instrument Co., Norcross, GA, USA) apparatus at −196C (77 K).

Three different methods, thermogravimetric analysis (TGA), alkali extraction, and water extraction, were explored to quantify the content of OC in BCPs (referred to as OCTGA, OCAE, and OCWE, respectively). The content of OCTGA was measured as the weight loss during the heating of BCPs from 30 to 300 C at a ramp of 10 C min−1 in a nitrogen flow (Han et al., 2013) using a TGA 8000 analyzer (PerkinElmer, USA). To measure the content of OCAE, the sample of BCPs was mixed with 0.1 M NaOH at a solid-to-solution ratio of 1:10 (ww) and magnetically stirred for 12 h, followed by filtration through a 0.45 µm filter membrane (Pall, USA) (Song et al., 2002). The filtrate was collected and acidified (pH 1.0 with 6 M HCl), and the total organic carbon (TOC) content of the sample was measured by a TOC analyzer (TOC-5000A, Shimadzu, Japan). For the three selected BCPs (grass, wheat, and household soot), the precipitates formed by acidification were further separated by centrifugation and dialyzed in deionized (DI) water by dialysis bag (500 Da, Union Carbide, USA) until no chloride ion was detected by AgNO3; then it was freeze-dried. The elemental compositions of the three prepared OCAE were measured by EA. To measure the content of OCWE and dissolved minerals, the suspended BCPs in DI water (BCPs-to-water ratio of 1:10 ww) was sonicated in a water bath for several minutes, and the mixture was filtered through a 0.45 µm membrane. The suspension and sonication procedure was repeated six times. The filtrate was collected and subjected to TOC analysis to obtain the content of OCWE. The concentrations of ionic constituents (Cl, NO3-, PO43-, SO42-, F, COO, C2O42-, Na+, NH4+, K+, Mg2+, Ca2+, Al3+) in the filtrate were measured using a Dionex ICS-1100 ion chromatograph (Thermo Scientific, USA). The cations were eluted using 20 mM methanesulfonic acid on a Dionex IonPac CS12A column (4 mm×250 mm), while the anions were eluted using an eluent of 4.5 mM Na2CO3 and 0.81 mM NaHCO3 on a Dionex IonPac AS14A column (4 mm×250 mm). The filtrate was further freeze-dried and baked at 600 C for 6 h to remove organic components. The remaining ash was weighed to determine the content of dissolved minerals in BCPs. A portion of the ash was extracted three times using DI water at a solid-to-solution ratio of 1:10 (ww) under sonication, and the salinity of the extract was measured by a ST3100C conductivity meter (OHAUS, USA). All reagents and chemicals used were of analytical reagent grade.

2.3 Measurement of hygroscopicity of BCPs

The hygroscopicity of BCPs at varying RH was measured by a gravimetric method combined with in situ DRIFTS. The water vapor sorption–desorption isotherms to BCPs under a range of continuous-stepwise water vapor pressures were acquired on a 3H-2000 PW multistation gravimetric-method steam adsorption instrument (Beijing, China) at 25 C using an approach similar to that in previous studies (Gu et al., 2017). The instrument consists of two main parts: a balance chamber to determine the sample mass to an accuracy ±1µg and a humidity chamber to regulate the water vapor pressure to the desired value as monitored online by a pressure sensor. Prior to testing, the BCPs (about 10 mg) were dried at 70 C under vacuum for 12 h to remove residual water vapor and set a baseline for comparison of water vapor adsorption behaviors among different samples. The amount of water sorbed to BCPs was monitored as the mass difference before and after sorption. The amount of water sorbed to the sample tube was measured and showed to be negligible (<0.05 % of the amount of water sorbed to BCPs). The water vapor pressures ranging from 10 % to 94 % RH were applied to the sorption isotherm branch in a stepwise increasing sequence and to the desorption isotherm branch in a stepwise decreasing sequence.

The kinetics of water sorption to BCPs was measured on a 100 mm closed quartz chamber (Jiangsu Province, China) using a gravimetric method similar to that in previous studies (Yuan et al., 2014). Approximately 100 mg of BCPs was dried at 70 C under vacuum for 12 h, weighed in a 10 mL beaker, and placed in a chamber under controlled humidity conditions based on different saturated aqueous salt solutions according to ASTM E104-02 (2007). The saturated solutions of CH3COOK, MgCl2, K2CO3, LiNO3, NaCl, KCl, and KNO3 provided RH values of 23 %, 33 %, 43 %, 47 %, 75 %, 84 %, and 94 %, respectively, at 25 C. The sample was continuously weighed and recorded over a period of time (48 h for low humidity and 96 h for high humidity) to monitor the amount of sorbed water. The RH was monitored in real time using a Honeywell HIH4000 hygrometer (USA) with measurement variance of less than 5 %. Sorption equilibrium was reached in the late stage of the experiment as evidenced by the stabilized constant value of sample mass. In addition to kinetic data, sorption isotherms were also collected for the seven selected RH levels using the measured mass under equilibrium conditions.

Samples of BCPs equilibrated at different RH levels were characterized by in situ DRIFTS using a Bruker Tensor 27 spectrometer equipped with a high-sensitivity mercury-cadmium-telluride (MCT) detector working under liquid N2 conditions and a chamber fitted with ZnSe windows (Harrick Scientific, USA). About 10 mg of BCPs pre-dried at 70 C under vacuum for 12 h was transferred to the chamber which was connected to a gas feeding system. The chamber was sealed and purged with high-purity N2 at a flow rate of 100 mL min−1 for at least 3 h to remove pre-adsorbed gases on BCPs and to minimize the interference of environmental CO2. The humidity in the chamber was regulated by mixing high-purity N2 and saturated water vapor at 25 C with varying ratios and monitored in real time by a hygrometer (Vaisala HUMITTER, Australia). The sample was equilibrated with the gas mixture in the chamber for at least 30 min to reach sorption equilibrium based on predetermined kinetics. The spectra were acquired by co-adding and averaging a plurality of 500 scans with a resolution of 4 cm−1 (Song and Boily, 2013). The amount of water sorbed to BCPs was monitored by the integrated intensity of the O−H stretching region from 2750 to 3660 cm−1 (Ghorai et al., 2011).

3 Results and discussion

3.1 Characteristics of BCPs

Bulk elemental compositions by EA and surface elemental compositions by XPS are summarized in Table S1. The bulk elemental compositions of all BCPs were dominated by C and O, together accounting for 54 %–96 % of the total. However, the bulk C and O compositions differed significantly among the 15 BCPs, ranging from 32 % to 76 % for C and from 16 % to 69 % for O. With the exception of the woody BCPs, the differences were apparent within each category of the herbal BCPs and the soot. Similarly, the surfaces of all the 15 BCPs were dominated by C and O; however, the differences of the surface C and O compositions among the 15 BCPs were much smaller compared to the bulk C and O compositions. Besides C and O, EA detected low amounts of N (<3.7 %) and S (<1.8 %), and XPS detected low amounts of N (<4.3 %), Si (<5.6 %), and S (<0.6 %). The contents of oxygen-containing groups in the 15 BCPs were qualitatively compared by the FTIR spectra (Fig. S1). All the tested BCPs except Weifu diesel soot showed characteristic peaks of esters (1700 cm−1), ketones (1613, 1100 cm−1), and phenols (1270 cm−1) (Keiluweit et al., 2010), generally with larger peak intensities observed for herbal BCPs and household soot.

Table 1Chemical, compositional, and pore properties of different BCPs.

a Content of organic carbon determined by TGA. b Content of alkali-extracted organic carbon determined by TOC analysis. c Content of water-extracted organic carbon determined by TOC analysis. d Determined by subtracting OCTGA content from total organic carbon content by EA. e Total pore volume determined by N2 adsorption at 0.97 atmosphere pressure. f Specific surface area (SSA) determined by the BET method.

Download Print Version | Download XLSX

Table 1 summarizes the contents of OC (OCTGA, OCAE, and OCWE) of the 15 BCPs by TGA, alkali extraction, and water extraction, respectively. For a given BCPs, the contents of the three types of OC differed pronouncedly, with an increasing order of OCWE< OCAE< OCTGA. The OC content also differed within the tested group of BCPs, ranging from 0.05 to 2.24 wt % for OCWE, from 0.14 to 8.39 wt % for OCAE, and from 4.48 to 15.25 wt % for OCTGA. Compared with the EC (graphitized carbon), the three types of OC are non-condensed, amorphous, and more rich in oxygen-containing functional groups, which was evidenced by the fact that the OCAE from the three selected BCPs (grass, wheat, and household soot) had markedly higher bulk compositions of O (results presented in Table S2). The EC content in BCPs was roughly assessed by subtracting the OCTGA content from the total organic carbon content measured by EA (results presented in Table 1). The calculated EC content negatively correlated with the OCAE content (R2=0.43, P=0.0079) for the examined group of BCPs. This relationship was reasonable as EC was comprised of mature, thermodynamically stable graphitized carbons, while OC was comprised of the less mature and less aromatic constituents remaining after pyrolysis. Except for Weifu diesel soot, the two woody BCPs had the highest EC, but the lowest OCAE and OCWE among the 15 BCPs.

The relative abundance of EC in BCPs was also assessed by Raman spectroscopy (Fig. S2). The spectra of all the tested BCPs were dominated by a D band at 1340 cm−1 and a G band at 1580 cm−1, which were ascribed to carbon network defects and the E2g mode of the graphitized carbon, respectively (Pimenta et al., 2007). Thus, the ratio of these two bands (IDIG) was inversely proportional to the in-plane crystallite size of graphitized carbons of BCPs (Cancado et al., 2006). The IDIG ratio of the woody BCPs (0.51–0.59) was less than those of the herbal BCPs (0.88–1.09) and the soot (0.77–1.12) (Table S3), suggesting larger sizes of graphitized carbons in the woody BCPs, which was consistent with the results of OC compositions.

The contents of dissolved minerals of the 15 BCPs are listed in Table 1, and their salinities in water extracts are listed in Table S5. The two woody BCPs had the lowest contents of dissolved minerals and salinities, while these contents in herbal BCPs and soot were higher and varied greatly. The mineral compositions characterized by XRF are listed in Table S6. Si- and K-rich minerals were the two major inorganic constituents in the herbal BCPs and woody BCPs. Moreover, these two types of BCPs generally contained trace amounts of S-, Cl-, Ca-, P-, Mg-, Na-, Fe-, and Al-rich minerals, with lower contents observed for the woody BCPs. The three soot samples had very different mineral compositions. Household soot was dominated by S-, Ca-, Si-, and Cl-rich minerals, diesel engine soot was dominated by S-, Ca-, and Fe-rich minerals, while Weifu diesel soot contained negligible mineral compositions. As reflected by the observed characteristic peaks and associated peak intensities in the XRD spectra (Fig. S3), the herbal BCPs and household soot contained more mineral species with higher contents than other BCPs, whereas the two woody BCPs and Weifu diesel soot contained the least species and contents of minerals. Potassium salts, amorphous silica, and sulfates were the major minerals in the herbal BCPs. Soot had the largest content of sulfates among the tested BCPs. According to the ion chromatograph analysis (results presented in Fig. S4 and Table S7), the major water-extracted cationic species from the tested BCPs were NH4+, K+, and Ca2+, and the major anionic species were SO42-, Cl, and C2O42-. The herbal BCPs had high contents of K+, C2O42-, and Cl, while the soot had high content of SO42-.

The Brunauer–Emmett–Teller (BET) specific surface area and total porosity measured by N2 adsorption are also summarized in Table 1. A huge disparity of specific surface area was shown among the 15 BCPs and among the BCPs within each category, ranging from 6 to 200 m2 g−1 for the soot, from 60 to 110 m2 g−1 for the woody BCPs, and from 0.1 to 52 m2 g−1 for the herbal BCPs. The micro- and mesoporosity of the 15 tested BCPs are summarized in Table S4. The herbal BCPs and woody BCPs were dominated by micropores (pore size <2 nm), which accounted for more than 50 % of the total pore volume. Alternatively, mesopores (50 nm > pore size >2 nm) were the main pore structure of the soot, accounting for more than 61 % of the total pore volume.

3.2 Hygroscopic properties of BCPs

Equilibrium water uptake. Figure 1 displays sorption and desorption isotherms of water vapor with BCPs plotted as equilibrium water uptake (mg g−1) by unit mass of BCPs under continuous-stepwise water vapor pressure conditions. Figure S5 displays the equilibrium sorption isotherms at selected humidity levels obtained by using saturated aqueous salt solutions. Under similar humidity conditions (80 % and 84 %), the water uptake by the 15 BCPs was very close between these two humidity regulation methods (Fig. S6), reflecting their technical validity. The woody BCPs showed very different sorption isotherm patterns from the herbal BCPs and soot. First, the water sorbing ability of the woody BCPs was much lower. The maximum water uptake observed at the highest RH (94 %) was approximately 65 mg g−1 by the woody BCPs but was more than 400 mg g−1 for the strongest sorbing herbal BCPs and soot. Second, much larger water-uptake disparities were observed within the group of herbal BCPs and the soot group than within the group of woody BCPs. Additionally, over the examined RH range (10 %–94 %), the water uptake by the woody BCPs increased slowly and linearly with the RH; however, for the herbal BCPs and soot, the water uptake increased more rapidly with the RH, especially under high humidity conditions (RH >70 %).

https://www.atmos-chem-phys.net/20/7941/2020/acp-20-7941-2020-f01

Figure 1Sorption and desorption isotherms of water vapor plotted as water uptake (mg g−1) vs. relative humidity (RH, %) at equilibrium for different BCPs. (a) Subgroup 1 of herbal BCPs. (b) Subgroup 2 of herbal BCPs. (c) Woody BCPs. (d) Soot. Data were collected from single-point measurements.

Download

To better understand the underlying mechanisms and factors controlling the hygroscopic properties of BCPs, linear relationships were built between the equilibrium water uptake and a wide variety of compositional and pore property parameters of the whole group of BCPs. Figure 2 displays regression relationships with contents of OCTGA, OCAE, EC, dissolved minerals, major ionic species (NH4+, Cl, SO42-, and C2O42-), and total porosity at 94 % RH. The regression relationships at 23 % RH are presented in Fig. S7. The regression accuracy (R2 and P) values at the seven different RH levels (23 %, 33 %, 43 %, 47 %, 75 %, 84 %, 94 %) are summarized in Table S8. Good positive correlations existed between the water uptake and the contents of OCTGA, OCAE, and dissolved minerals under high humidity conditions (Fig. 2a, b, d). The highest regression accuracy values obtained were R2=0.82 and P<0.0001 for OCTGA at 84 % RH, R2=0.80 and P=0.001 for OCAE at 94 % RH, and R2=0.86 and P=0.0001 for dissolved minerals at 94 % RH. However, the correlations with these constituents became much weaker under low humidity conditions (R2=0.10–0.32, P=0.247–0.028 at RH =23 %). It can be concluded that the hygroscopicity of herbal BCPs and soot under high humidity conditions was mainly controlled by the contents of OC and dissolved minerals. On the other hand, the low water sorbing ability of the woody BCPs was due to the very low contents of these constituents. As indicated by the elemental analysis results (Table S2), the OC constituents in the three representative BCPs (grass, red pine, and household soot) contained large amounts of oxygen-containing groups, which expectedly had very high hygroscopicity (Xiao et al., 2013). The very strong water retention ability of dissolved minerals in BCPs was understandable due to the strong hydration of mineral surfaces and ionic constituents. No correlation was observed between the water uptake of BCPs and the total organic carbon content within the whole examined RH range. Notably, a negative correlation was observed with the EC content (Fig. 2c), especially under high humidity conditions (R2=0.54, P=0.0019 at 94 % RH). Compared with the OC in BCPs, the EC was comprised mainly of hydrophobic fused aromatic hydrocarbons and had much lower amounts of oxygen-containing groups, resulting in the very low water sorbing ability.

The above one-factor linear correlation analysis indicted that at high RH the hygroscopicity of BCPs was dominated by OC and dissolved minerals. Consistently, a better positive correlation (R2=0.90, P<0.0001) could be obtained between the equilibrium water uptake and the contents of OCTGA and dissolved mineral by binary linear regression for the tested group of BCPs (Fig. S8). Interestingly, the correlation relationship became poorer as the RH level gradually decreased, and the worst correlation was shown at 23 % RH (R2=0.21, P=0.028). The results suggested that the hygroscopicity of BCPs at low RH was controlled by different factors.

https://www.atmos-chem-phys.net/20/7941/2020/acp-20-7941-2020-f02

Figure 2Relationships between equilibrium water uptake (mg g−1) vs. compositional and pore property parameters for the group of BCPs at 94 % relative humidity. (a) TGA-measured organic carbon (OCTGA). (b) Alkali-extracted organic carbon (OCAE). (c) Elemental carbon (EC). (d) Dissolved minerals. (e) Ammonium (NH4+). (f) Chloride (Cl). (g) Oxalate (C2O42-). (h) Sulfate (SO42-). (i) Total porosity.

Download

At 94 % RH, relatively good positive correlations were observed with NH4+ and Cl (R2=0.50–0.70, P=0.0001–0.0034) but not with SO42- (R2=0.24, P=0.06) or C2O42- (R2=0.002, P=0.89) (Fig. 2e–h). No correlation (R2=0.08, P=0.30) was observed with the total porosity of BCPs at 94 % RH (Fig. 2i). Consistently, previous studies reported that chloride salts in biomass burning aerosols had high hygroscopicity (Jing et al., 2017; Posfai et al., 2003). The poor correlation observed for SO42- was ascribed to the low hygroscopicity of CaSO4 and K2SO4, as evidenced by their very high deliquescent relative humidity (96 %–97 %) (Freney et al., 2007; Preturlan et al., 2019). It is noteworthy that the content of SO42- positively correlated with the contents of Ca2+ (R2=0.74, P<0.0001) and K+ (R2=0.69, P=0.0008) for the tested BCPs. On the other hand, the poor correlation observed for C2O42- was likely due to the formation of less water-soluble compounds (e.g., CaC2O4 and H2C2O4) that might depress the hygroscopicity (Ma et al., 2013).

The positive correlations observed with NH4+ and Cl at 94 % RH disappeared at 23 % RH. Alternatively, a relatively good negative correlation (R2=0.42, P=0.0095) with the total porosity was shown at 23 % RH (Fig. S7i). Similarly, a weak negative correlation (R2=0.21, P=0.083) was shown with the EC content at 23 % RH. The consistency between the total porosity and the EC content was likely due to the dominant role of graphitized carbons (EC) in forming rigid pore structures of BCPs (Han et al., 2014). On the contrary, a weak positive correlation (R2=0.32, P=0.028) was observed between the water uptake and the OCTGA content at 23 % RH, indicating that the OC constituents were an important factor contributing to the overall water uptake by BCPs under low humidity conditions.

As can be seen from the sorption–desorption isotherms in Fig. 1, some herbal BCPs (amaranth, peanuts, wheat, millet, pea, and sorghum) and soot (diesel engine soot and household soot) showed a strong hysteresis effect (irreversible sorption), whereas none of the woody BCPs showed a hysteresis effect. Irreversible sorption would lower the release of sorbed water molecules from BCPs in the atmosphere when the RH changes from a high level to a low level. The observed hysteresis effect of herbal BCPs and soot likely stemmed from their relatively high contents of OC and/or dissolved minerals (such as wheat and household soot). Sorbing water molecules could cause strong and irreversible hydration of organic acids (Petters et al., 2017) and dissolution or phase change of minerals (Adapa et al., 2018), consequently leading to hysteresis effect due to nonidentical structures of BCPs between the sorption and desorption branches even at the same RH. The negligible hysteresis effect observed on the two woody BCPs could be attributed to their very low contents of OC and dissolved minerals.

The equilibrium water uptake by BCPs was further investigated by DRIFTS. The spectra of representative BCPs (grass, red pine, and household soot) at varying RH are presented in Fig. 3a–c. Figure 3d compares the water uptake at 23 % RH monitored by the integrated intensity of the O−H stretching region from 2750 to 3660 cm−1 (Ghorai et al., 2011), along with the water uptake measured by the multistation gravimetric method for eight selected BCPs. The identified bands of sorbed water molecules included a combination mode of symmetric stretch around 3423 cm−1 and asymmetric stretch stretch around 3253 cm−1 (Gustafsson et al., 2005). The broad feature peak centered at 2100 cm−1 was assigned to a combined band of bending, libration, and hindered translation modes of water, while the peak centered at 1640 cm−1 was attributed to the bending mode of water (Ma et al., 2010). The intensities of these peaks/bands increased with increasing RH. As assessed by the integrated intensity of the O−H stretching region (see insets in Fig. 3a–c), the water uptake by grass and household soot increased gradually with RH from 12 % to 80 %; however, the water uptake by red pine rapidly reached saturation at about 28 % RH and kept constant when the RH was further increased. With the exception of Weifu diesel soot, the disparity pattern of water uptake by the eight selected BCPs at 23 % RH monitored by DRIFTS was similar to that monitored by the multi-station gravimetric method (Fig. 3d). However, the disparities were very large between these two methods at 80 % RH (Fig. S9), which was probably because the saturated effect encountered in detection of sorbed water molecules by FTIR (Gustafsson et al., 2005) became worse under high humidity conditions. Moreover, the DRIFTS signals of sorbed water molecules might be influenced by the distribution of sorption sites (e.g., minerals vs. OC and exterior vs. interior), and the caused effects might lead to larger deviations under high humidity conditions.

https://www.atmos-chem-phys.net/20/7941/2020/acp-20-7941-2020-f03

Figure 3Diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) characterization of equilibrium water uptake by BCPs. (a–c) Spectra for the three representative BCPs (grass, red pine, and household soot) equilibrated at varying relative humidity (RH) levels. (d) Comparison of equilibrium water uptake measured as integrated area of O−H stretching region (2750–3660 cm−1) between eight selected BCPs at 23 % relative humidity. Error bars represent standard variations from duplicate samples. Insets in panels (a–c) present water uptake measured as integrated area of O−H stretching region against RH.

Download

https://www.atmos-chem-phys.net/20/7941/2020/acp-20-7941-2020-f04

Figure 4Sorption kinetics of water vapor plotted as water uptake (mg g−1) vs. time (h) at 94 % relative humidity. (a) Subgroup 1 of herbal BCPs. (b) Subgroup 2 of herbal BCPs. (c) Woody BCPs. (d) Soot. Error bars represent standard variations from duplicate samples.

Download

Kinetic water uptake. Figure 4 displays the water vapor sorption kinetics to the 15 BCPs at 94 % RH obtained by saturated aqueous salt solutions. The sorption kinetics at 33 % RH are presented in Fig. S10. The two woody BCPs exhibited similar kinetics curves; however, the herbal BCPs and soot showed very different kinetic patterns within each group. The kinetic data were fitted to the pseudo-first-order and pseudo-second-order models, dqt/dt=k1 (qe-qt) and dqt/dt=k2 (qeqt)2, respectively, where qt was the sorbed concentration at time t, qe was the equilibrium sorbed concentration, and k1 and k2 were the pseudo-first-order and pseudo-second-order rate constants, respectively. Note that these two kinetic models were applied only for quantitative comparison of apparent sorption kinetics among different BCPs but not for illustration of sorption mechanisms. The fitting parameters (qe, k1, k2) for the three selected RH levels (33 %, 47 %, and 94 %) are summarized in Tables S9–S10. The pseudo-second-order model (R2>0.97) fits the data better than the pseudo-first-order model (R2=0.80–0.99). The calculated k2 differed greatly among the BCPs within the group of herbal BCPs and the soot group but was very close between the two woody BCPs. For a given BCPs, the k2 at a lower RH level was significantly larger than that at a higher RH level. Similar results were reported in previous studies on sorption kinetics of water vapor to activated carbon (Ohba and Kaneko, 2011; Ribeiro et al., 2008). Under low humidity conditions, sorption of water vapor mainly occurs at the active, high-energy binding sites, and the sorption kinetics is fast; alternatively, under high humidity conditions, sorption is governed by the slow pore-filling/condensation process of water molecules within the pores of activated carbon via formation of water clusters around the water molecules already sorbed at the active sites (Nguyen and Bhatia, 2011; Rosas et al., 2008). Due to the small molecular size (0.0958 nm×0.151 nm, ChemDraw 3D), water molecules could well penetrate into the micropores of BCPs and form water clusters via intermolecular hydrogen bonding. The sorbing ability order of the different types of BCPs varied depending on the examined RH. At 33 % RH, the k2 roughly followed a decreasing order of soot (0.5–5.25×10-5 g mg−1 s−1) > woody BCPs (1.57–1.90×10-5 g mg−1 s−1) > herbal BCPs (0.34–2.07×10-5 g mg−1 s−1); however, no clear trend was shown for high humidity conditions (e.g., RH =94 %), mainly resulting from the larger variances within the group of herbal BCPs and soot group.

https://www.atmos-chem-phys.net/20/7941/2020/acp-20-7941-2020-f05

Figure 5Relationships between pseudo-second-order water uptake rate constant (k2) (g mg−1 s−1) vs. compositional and pore property parameters for the group of BCPs at 94 % relative humidity. (a) TGA-measured organic carbon (OCTGA). (b) Alkali-extracted organic carbon (OCAE). (c) Elemental carbon (EC). (d) Dissolved minerals. (e) Ammonium (NH4+). (f) Chloride (Cl). (g) Oxalate (C2O42-). (h) Sulfate (SO42-). (i) Total porosity.

Download

Like for the equilibrium water uptake, the relationships were built between the k2 and the contents of OCTGA, OCAE, EC, dissolved minerals, major ionic species (NH4+, Cl, C2O42- and SO42-), and total porosity at 94 % RH (Fig. 5). The regression relationships at 33 % RH are presented in Fig. S11. The regression accuracy (R2 and P) values at 33 %, 47 %, and 94 % RH are summarized in Table S11. At 94 % RH, a strong positive correlation was observed between the k2 and the total porosity (R2=0.82, P<0.0001), likely resulting from the pore-filling/condensation mechanism. A similar mechanism has been previously proposed to account for the positive correlation observed between the water vapor sorption kinetics and the porosity of activated carbon under high humidity conditions (Nakamura et al., 2010; Velasco et al., 2016). Likewise, a positive correlation (R2=0.45, P=0.0061) was observed between the k2 and the EC content, which could be ascribed to the formation of rigid pore structures dominantly by graphitized carbons (EC) (Han et al., 2014). The correlation between k2 and total porosity observed at 94 % RH disappeared under low and medium humidity conditions. At 33 % RH, relatively good positive correlations were observed with the contents of OCTGA (R2=0.47, P=0.0046), OCAE (R2=0.44, P=0.007), NH4+ (R2=0.77, P<0.0001), and Cl (R2=0.60, P=0.0007) but not with SO42− (R2=0.11, P=0.2286) or dissolved minerals (R2=0.08, P=0.31). The positive correlations with these constituents were not shown under medium and high humidity conditions. Thus, the constituents of OC and NH4+ and Cl salts likely provided the primary high-affinity active sites for sorption of water vapor under low humidity conditions.

4 Conclusions

The hygroscopic properties of 15 different BCPs (herbal, woody, and soot) were systematically investigated using a gravimetric method and DRIFTS. The mechanisms and factors controlling the equilibrium and kinetic water uptake differed among the types of BCPs and depended heavily on the humidity conditions. Linear correlation analyses indicated that the equilibrium water uptake by the tested group of BCPs positively correlated to the contents of OC (OCTGA and OCAE), dissolved minerals, and NH4+ and Cl salts under high humidity conditions and weakly to the contents of OC only under low humidity conditions. By contrast, negative correlations were observed between the equilibrium water uptake and the EC content. The low water uptake by the woody BCPs could be attributed to the very low contents of OC and dissolved minerals. Thus, the equilibrium water uptake by BCPs was mainly controlled by the hygroscopic constituents of OC and dissolved minerals or salts. The kinetic water uptake by the BCPs could be well described by the pseudo-second-order kinetic model. The calculated rate constant (k2) positively correlated to the contents of OCTGA, OCAE, and NH4+ and Cl salts under low humidity conditions and to the total porosity only under high humidity conditions. The fast water uptake kinetics under low humidity conditions was attributed to the binding to high-affinity active sites (OC and salts), which could sorb water vapor fast but had limited contents. Alternatively, the slow water uptake kinetics under high humidity conditions was attributed to pore-filling and condensation of water molecules within the micro- and mesopores of BCPs. This study highlights that the hygroscopic properties of BCPs rely on compositional and structural properties of BCPs as well as humidity conditions.

Data availability

The underlying research data used in this study are available. Readers can access the data directly in the article and the Supplement or by contacting Dongqiang Zhu via zhud@pku.edu.cn.

Supplement

The supplement related to this article is available online at: https://doi.org/10.5194/acp-20-7941-2020-supplement.

Author contributions

DZ provided the original idea and prepared the paper with contributions from all co-authors. MW and YC designed and conducted the research, and HF and XQ were involved in the development of the analysis methods. BL and ST reviewed the written document.

Competing interests

The authors declare that they have no conflict of interest.

Acknowledgements

This work was supported by the National Natural Science Foundation of China (grant nos. 21777002, 21920102002, and 41991331).

Financial support

This research has been supported by the National Natural Science Foundation of China (grant nos. 21777002, 21920102002, 41991331).

Review statement

This paper was edited by Anne Perring and reviewed by two anonymous referees.

Appendix A

Detailed characterization results of the different BCPs can be found in Tables S1-S7. Table S8 lists accuracy (R2 and P) values for regression on equilibrium water uptake against different variables. Tables S9–S10 present pseudo-first/second-order kinetic model fitting parameters. Table S11 lists accuracy (R2 and P) values for regression on k2 against different variables. Figures S1–S4 displays spectroscopic characterization of different BCPs. Figure S5 displays sorption isotherms at selected humidity obtained by using saturated aqueous salt solutions. Figure S6 compares equilibrium water uptake measured by the two different gravimetric methods. Figure S7 displays relationships between equilibrium water uptake and different variables at 23 % RH. Figure S8 displays the relationship between measured values of equilibrium water uptake at 94 % relative humidity vs. predicted values obtained by binary factor regression based on contents of OCTGA and dissolved minerals for the group of BCPs. Figure S9 compares equilibrium water uptake measured by DRIFTS and gravimetric method at high RH. Figure S10 displays sorption kinetics of water uptake at 33 % RH. Figure S11 displays relationships between k2 and different variables at 33 % RH.

References

Adapa, S., Swamy, D. R., Kancharla, S., Pradhan, S., and Malani, A.: Role of mono- and divalent surface cations on the structure and adsorption behavior of water on mica surface, Langmuir, 34, 14472–14488, https://doi.org/10.1021/acs.langmuir.8b01128, 2018. 

Andreae, M. O. and Gelencsér, A.: Black carbon or brown carbon? The nature of light-absorbing carbonaceous aerosols, Atmos. Chem. Phys., 6, 3131–3148, https://doi.org/10.5194/acp-6-3131-2006, 2006. 

Archanjo, B. S., Araujo, J. R., Silva, A. M., Capaz, R. B., Falcao, N. P. S., Jorio, A., and Achete, C. A.: Chemical analysis and molecular models for calcium-oxygen-carbon interactions in black carbon found in fertile Amazonian anthrosoils, Environ. Sci. Technol., 48, 7445–7452, 2014. 

Bond, T. C., Doherty, S. J., Fahey, D. W., Forster, P. M., Berntsen, T., DeAngelo, B. J., Flanner, M. G., Ghan, S., Kärcher, B., Koch, D., Kinne, S., Kondo, Y., Quinn, P. K., Sarofim, M. C., Schultz, M. G., Schulz, M., Venkataraman, C., Zhang, H., Zhang, S., Bellouin, N., Guttikunda, S. K., Hopke, P. K., Jacobson, M. Z., Kaiser, J. W., Klimont, Z., Lohmann, U., Schwarz, J. P., Shindell, D., Storelvmo, T., Warren, S. G., and Zender, C. S.: Bounding the role of black carbon in the climate system: A scientific assessment, J. Geophys. Res.-Atmos., 118, 5380–5552, 2013. 

Cancado, L. G., Takai, K., Enoki, T., Endo, M., Kim, Y. A., and Mizusaki, H.: General equation for the determination of the crystallite size L-a of nanographite by Raman spectroscopy, Appl. Phys. Lett., 88, 163106, https://doi.org/10.1063/1.2196057, 2006 

Carrico, C. M., Petters, M. D., Kreidenweis, S. M., Sullivan, A. P., McMeeking, G. R., Levin, E. J. T., Engling, G., Malm, W. C., and Collett Jr., J. L.: Water uptake and chemical composition of fresh aerosols generated in open burning of biomass, Atmos. Chem. Phys., 10, 5165–5178, https://doi.org/10.5194/acp-10-5165-2010, 2010. 

Day, D. E., Hand, J. L., Carrico, C. M., Engling, G., and Malm, W. C.: Humidification factors from laboratory studies of fresh smoke from biomass fuels, J. Geophys. Res., 111, D22202, https://doi.org/10.1029/2006JD007221, 2006. 

Fletcher, A. J., Uygur, Y., and Mark Thomas, K.: Role of surface functional groups in the adsorption kinetics of water vapor on microporous activated carbons, J. Phys. Chem. C., 111, 8349–8359, 2007. 

Freney, E. J., Martin, S. T., and Buseck, P. R.: Deliquescence measurements of potassium salts, American Geophysical Union, Fall Meeting, December, abstract id. A23B-1255, 2007. 

Ghorai, S., Laskin, A., and Tivanski, A. V.: Spectroscopic evidence of keto-enol tautomerism in deliquesced malonic acid particles, J. Phys. Chem. A., 115, 4373–4380, 2011. 

Gu, W., Li, Y., Zhu, J., Jia, X., Lin, Q., Zhang, G., Ding, X., Song, W., Bi, X., Wang, X., and Tang, M.: Investigation of water adsorption and hygroscopicity of atmospherically relevant particles using a commercial vapor sorption analyzer, Atmos. Meas. Tech., 10, 3821–3832, https://doi.org/10.5194/amt-10-3821-2017, 2017. 

Gustafsson, R. J., Orlov, A., Badger, C. L., Griffiths, P. T., Cox, R. A., and Lambert, R. M.: A comprehensive evaluation of water uptake on atmospherically relevant mineral surfaces: DRIFT spectroscopy, thermogravimetric analysis and aerosol growth measurements, Atmos. Chem. Phys., 5, 3415–3421, https://doi.org/10.5194/acp-5-3415-2005, 2005. 

Haddrell, A. E., Davies, J. F., and Reid, J. P.: Dynamics of particle size on inhalation of environmental aerosol and impact on deposition fraction, Environ. Sci. Technol., 49, 14512–14521, 2015. 

Han, C., Liu, Y., and He, H.: Role of organic carbon in heterogeneous reaction of NO2 with soot, Environ. Sci. Technol., 47, 3174–3181, 2013. 

Han, L. F., Sun, K., Jin, J., Wei, X., Xia, X. H., Wu, F. C., Gao, B., and Xing, B. S.: Role of structure and microporosity in phenanthrene sorption by natural and engineered organic matter, Environ. Sci. Technol., 48, 11227–11234, 2014. 

Jing, B., Peng, C., Wang, Y., Liu, Q., Tong, S., Zhang, Y., and Ge, M.: Hygroscopic properties of potassium chloride and its internal mixtures with organic compounds relevant to biomass burning aerosol particles, Sci. Rep., 2, 43573, https://doi.org/10.1038/srep43572, 2017. 

Keiluweit, M., Nico, P. S., Johnson, M. G., and Kleber, M.: Dynamic molecular structure of plant biomass-derived black carbon (biochar), Environ. Sci. Technol., 44, 1247–1253, 2010. 

Lewis, K. A., Arnott, W. P., Moosmüller, H., Chakrabarty, R. K., Carrico, C. M., Kreidenweis, S. M., Day, D. E., Malm, W. C., Laskin, A., Jimenez, J. L., Ulbrich, I. M., Huffman, J. A., Onasch, T. B., Trimborn, A., Liu, L., and Mishchenko, M. I.: Reduction in biomass burning aerosol light absorption upon humidification: roles of inorganically-induced hygroscopicity, particle collapse, and photoacoustic heat and mass transfer, Atmos. Chem. Phys., 9, 8949–8966, https://doi.org/10.5194/acp-9-8949-2009, 2009. 

Li, J., Posfai, M., Hobbs, P. V., and Buseck, P. R.: Individual aerosol particles from biomass burning in southern Africa: 2. Compositions and aging of inorganic particles, J. Geophys. Res., 108, 8484, https://doi.org/10.1029/2002JD002310, 2003. 

Lian, F. and Xing, B.: Black carbon (biochar) in water/soil environments: Molecular structure, sorption, stability, and potential risk, Environ. Sci. Technol., 51, 13517–13532, 2017. 

Liu, P., Song, M., Zhao, T., Gunthe, S. S., Ham, S., He, Y., Qin, Y. M., Gong, Z., Amorim, J. C., Bertram, A. K., and Martin, S. T.: Resolving the mechanisms of hygroscopic growth and cloud condensation nuclei activity for organic particulate matter, Nat. Commun., 9, 4076, https://doi.org/10.1038/s41467-018-06622-2, 2018. 

Ma, Q., He, H., and Liu, Y.: In situ DRIFTS study of hygroscopic behavior of mineral aerosol, J. Environ. Sci., 22, 555–560, 2010. 

Ma, Q., He, H., and Liu, C.: Hygroscopic properties of oxalic acid and atmospherically relevant oxalates, Atmos. Environ., 69, 281–288, 2013. 

Matthews, H. D., Gillett, N. P., Stott, P. A., and Zickfeld, K.: The proportionality of global warming to cumulative carbon emissions, Nature, 459, 829–832, 2009. 

Nakamura, M., Ohba, T., Branton, P., Kanoh, H., and Kaneko, K.: Equilibrium-time and pore width dependent hysteresis of water adsorption isotherm on hydrophobic microporous carbons, Carbon, 48, 2549–2553, 2010. 

Nguyen, T. X. and Bhatia, S. K.: How water adsorbs in hydrophobic nanospaces, J. Phys. Chem. C, 115, 16606–16612, 2011. 

Nienow, A. M. and Roberts, J. T.: Heterogeneous chemistry of carbon aerosols, Rev. Phys. Chem., 57, 105–128, 2006. 

Ohba, T. and Kaneko, K.: Kinetically forbidden transformations of water molecular assemblies in hydrophobic micropores, Langmuir, 27, 7609–7613, 2011. 

Petters, S. S., Pagonis, D., Claflin, M. S., Levin, E. J. T., Petters, M. D., Ziemann, P. J., and Kreidenweis, S. M.: Hygroscopicity of organic compounds as a function of carbon chain length and carboxyl, hydroperoxy, and carbonyl functional groups, J. Phys. Chem. A., 121, 5164–5174, 2017. 

Pimenta, M. A., Dresselhaus, G., Dresselhaus, M. S., Cancado, L. G., Jorio, A., and Saito, R.: Studying disorder in graphite-based systems by Raman spectroscopy, Phys. Chem. Chem. Phys., 9, 1276–1291, 2007. 

Posfai, M., Simonics, R., Li, J., Hobbs, P. V., and Buseck, P. R.: Individual aerosol particles from biomass burning from southern Africa: 1. Compositions and size distributions of carbonaceous particles, J. Geophys. Res., 108, 8483, https://doi.org/10.1029/2002JD002291, 2003. 

Powelson, M. H., Espelien, B. M., Hawkins, L. N., Galloway, M. M., and De Haan, D. O.: Brown carbon formation by aqueous-phase carbonyl compound reactions with amines and ammonium sulfate, Environ. Sci. Technol., 48, 985–993, 2014. 

Preturlan, J. G. D., Vieille, L., Quiligotti, S., and Favergeon, L.: Comprehensive thermodynamic study of the calcium sulfate–water vapor system. Part 1: experimental measurements and phase equilibria, Ind. Eng. Chem. Res., 58, 9596–9606, 2019. 

Qiu, C., Khalizov, A. F., and Zhang, R.: Soot aging from OH-Initiated oxidation of toluene, Environ. Sci. Technol., 46, 9464–9472, 2012. 

Reid, J. S., Koppmann, R., Eck, T. F., and Eleuterio, D. P.: A review of biomass burning emissions part II: intensive physical properties of biomass burning particles, Atmos. Chem. Phys., 5, 799–825, https://doi.org/10.5194/acp-5-799-2005, 2005. 

Ribeiro, A. M., Sauer, T. P., Grande, C. A., Moreira, R. F. P. M., Loureiro, J. M., and Rodrigues, A. E.: Adsorption equilibrium and kinetics of water vapor on different adsorbents, Ind. Eng. Chem. Res., 47, 7019–7026, 2008. 

Rosas, J. M., Bedia, J., Miraso, J. R., and Cordero, T.: Preparation of hemp-derived activated carbon monoliths, adsorption of water vapor, Ind. Eng. Chem. Res., 47, 1288–1296, 2008. 

Schwarz, J. P., Spackman, J. R., Fahey, D. W., Gao, R. S., Lohmann, U., Stier, P., Watts, L. A., Thomson, D. S., Lack, D. A., Pfister, L., Mahoney, M. J., Baumgardner, D., Wilson, J. C., and Reeves, J. M.: Coatings and their enhancement of black carbon light absorption in the tropical atmosphere, J. Geophys. Res., 113, D03203, https://doi.org/10.1029/2007JD009042, 2008. 

Seisel, S., Pashkova, A., Lian, Y., and Zellner, R.: Water uptake on mineral dust and soot: a fundamental view of the hydrophilicity of atmospheric particles, Faraday Discuss., 130, 437–451, 2005. 

Sjogren, S., Gysel, M., Weingartner, E., Baltensperger, U., Cubison, M. J., Coe, H., Zardini, A. A., Marcolli, C., Krieger, U. K., and Peter, T.: Hygroscopic growth and water uptake kinetics of two-phase aerosol particles consisting of ammonium sulfate, adipic and humic acid mixtures, Aerosol Sci., 38, 157–171, 2007. 

Song, W. and Boily, J. F.: Water vapor adsorption on goethite, Environ. Sci. Technol., 47, 7171–7177, 2013.  

Song, J., Peng, P., and Huang, W.: Black carbon and kerogen in soils and sediments. 1. Quantification and characterization, Environ, Sci. Technol., 36, 3960–3967, 2002. 

Stanislav, V., Vassilev, D. B., Andersen, L. K., and Vassileva, C. G.: An overview of the composition and application of biomass ash. Part 1. Phase-mineral and chemical composition and classification, Fuel, 105, 40–76, 2013. 

Stemmler, K., Vlasenko, A., Guimbaud, C., and Ammann, M.: The effect of fatty acid surfactants on the uptake of nitric acid to deliquesced NaCl aerosol, Atmos. Chem. Phys., 8, 5127–5141, https://doi.org/10.5194/acp-8-5127-2008, 2008. 

Suda, S. R., Petters, M. D., Yeh, G. K. Strollo, C., Matsunaga, A., Faulhaber, A., Ziemann, P. J., Prenni, A. J., Carrico, C. M., Sullivan, R. C., and Kreidenweis, S. M.: Influence of functional groups on organic aerosol cloud condensation nucleus activity, Environ. Sci. Technol., 48, 10182–10190, 2014. 

Velasco, L. F., Remy Guillet, N. R., Dobos, G., Thommes, M., and Lodewyckx, P.: Towards a better understanding of water adsorption hysteresis in activated carbons by scanning isotherms, Carbon, 96, 753–758, 2016. 

Wei, S., Zhu, M., Fan, X., Song, J., Peng, P., Li, K., Jia, W., and Song, H.: Influence of pyrolysis temperature and feedstock on carbon fractions of biochar produced from pyrolysis of rice straw, pine wood, pig manure and sewage sludge, Chemosphere, 218, 624–631, 2019. 

Xiao, J., Liu, Z., Kim, K., Chen, Y., Yan, J., Li, Z., and Wang, W.: S/O-Functionalities on modified carbon materials governing adsorption of water vapor, J. Phys. Chem. C., 117, 23057–23065, 2013. 

Xiao, X., Chen, B., Chen, Z., Zhu, L., and Schnoor, J. L.: Insight into multiple and multilevel structures of biochars and their potential environmental applications: A critical review, Environ. Sci. Technol., 52, 5027–5047, 2018. 

Yuan, W., Li, X., Pan, Z., Connell, L. D., Li, S., and He, J.: Experimental investigation of interactions between water and a lower silurian chinese shale, Energy Fuels, 28, 4925–4933, 2014. 

Yuan, J.-F., Huang, X.-F., Cao, L.-M., Cui, J., Zhu, Q., Huang, C.-N., Lan, Z.-J., and He, L.-Y.: Light absorption of brown carbon aerosol in the PRD region of China, Atmos. Chem. Phys., 16, 1433–1443, https://doi.org/10.5194/acp-16-1433-2016, 2016. 

Zhang, R., Khalizov, A., Wang, L., Hu. M., and Xu, W.: Nucleation and growth of nanoparticles in the atmosphere, Chem. Rev., 112, 1957–2011, 2012. 

Zuend, A., Marcolli, C., Booth, A. M., Lienhard, D. M., Soonsin, V., Krieger, U. K., Topping, D. O., McFiggans, G., Peter, T., and Seinfeld, J. H.: New and extended parameterization of the thermodynamic model AIOMFAC: calculation of activity coefficients for organic-inorganic mixtures containing carboxyl, hydroxyl, carbonyl, ether, ester, alkenyl, alkyl, and aromatic functional groups, Atmos. Chem. Phys., 11, 9155–9206, https://doi.org/10.5194/acp-11-9155-2011, 2011. 

Download
Short summary
The mechanism and factors controlling the hygroscopicity of black-carbon-containing particles (BCPs) from different carbon sources are not well understood. We thoroughly characterized the chemical and compositional properties of 15 samples of BCPs from different sources (wood, herb, and soot) and further investigated their hygroscopicity. Depending on the carbon source, organic carbon and dissolved mineral contents were key determinants of the equilibrium and kinetics of water uptake by BCPs.
Altmetrics
Final-revised paper
Preprint