Journal cover Journal topic
Atmospheric Chemistry and Physics An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 5.509 IF 5.509
  • IF 5-year value: 5.689 IF 5-year 5.689
  • CiteScore value: 5.44 CiteScore 5.44
  • SNIP value: 1.519 SNIP 1.519
  • SJR value: 3.032 SJR 3.032
  • IPP value: 5.37 IPP 5.37
  • h5-index value: 86 h5-index 86
  • Scimago H index value: 161 Scimago H index 161
Volume 12, issue 18
Atmos. Chem. Phys., 12, 8763-8775, 2012
https://doi.org/10.5194/acp-12-8763-2012
© Author(s) 2012. This work is distributed under
the Creative Commons Attribution 3.0 License.

Special issue: An integrated approach to study atmospheric greenhouse and...

Atmos. Chem. Phys., 12, 8763-8775, 2012
https://doi.org/10.5194/acp-12-8763-2012
© Author(s) 2012. This work is distributed under
the Creative Commons Attribution 3.0 License.

Research article 28 Sep 2012

Research article | 28 Sep 2012

Calibration of column-averaged CH4 over European TCCON FTS sites with airborne in-situ measurements

M. C. Geibel1,*, J. Messerschmidt2, C. Gerbig1, T. Blumenstock3, H. Chen1,**, F. Hase3, O. Kolle1, J. V. Lavrič1, J. Notholt2, M. Palm2, M. Rettinger4, M. Schmidt5, R. Sussmann4, T. Warneke2, and D. G. Feist1 M. C. Geibel et al.
  • 1Max Planck Institute for Biogeochemistry (MPI-BGC), Jena, Germany
  • 2Institute of Environmental Physics (IUP), University of Bremen, Bremen, Germany
  • 3IMK-ASF, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
  • 4IMK-IFU, Karlsruhe Institute of Technology (KIT), Garmisch-Partenkirchen, Germany
  • 5Laboratoire des Sciences du Climat et l'Environnement (LSCE), Gif-sur-Yvette, France
  • *now at: Department for Applied Environmental Research (ITM), Stockholm University, Stockholm, Sweden
  • **now at: NOAA Earth System Research Laboratory, Boulder, CO, USA

Abstract. In September/October 2009, six European ground-based Fourier Transform Spectrometers (FTS) of the Total Carbon Column Observation Network (TCCON) were calibrated for the first time using aircraft measurements. The campaign was part of the Infrastructure for Measurement of the European Carbon Cycle (IMECC) project.

During this campaign, altitude profiles of several trace gases and meteorological parameters were taken close to the FTS sites (typically within 1–2 km distance for flight altitudes below 5000 m). Profiles of CO2, CH4, CO and H2O were measured continuously. N2O, H2, and SF6 were later derived from flask measurements. The aircraft data had a vertical coverage ranging from approximately 300 to 13 000 m, corresponding to ~80% of the total atmospheric column seen by the FTS.

This study summarizes the calibration results for CH4. The resulting calibration factor of 0.978 ± 0.002 (±1 σ) from the IMECC campaign agreed very well with the results that Wunch et al. (2010) had derived for TCCON instruments in North America, Australia, New Zealand, and Japan using similar methods. By combining our results with the data of Wunch et al. (2010), the uncertainty of the calibration factor could be reduced by a factor of three (compared to using only IMECC or only Wunch et al. (2010) data).

A careful analysis of the calibration method used by Wunch et al. (2010) revealed that the incomplete vertical coverage of the aircraft profiles can lead to a bias in the calibration factor. This bias can be compensated with a new iterative approach that we developed. Using this improved method, we derived a significantly lower calibration factor of 0.974 ± 0.002 (±1 σ). This corresponds to a correction of all TCCON CH4 measurements by roughly −7 ppb.