Journal cover Journal topic
Atmospheric Chemistry and Physics An interactive open-access journal of the European Geosciences Union
Journal topic

Journal metrics

Journal metrics

  • IF value: 5.509 IF 5.509
  • IF 5-year value: 5.689 IF 5-year 5.689
  • CiteScore value: 5.44 CiteScore 5.44
  • SNIP value: 1.519 SNIP 1.519
  • SJR value: 3.032 SJR 3.032
  • IPP value: 5.37 IPP 5.37
  • h5-index value: 86 h5-index 86
  • Scimago H index value: 161 Scimago H index 161
Volume 10, issue 21 | Copyright

Special issue: GOMOS (Global Ozone Monitoring by Occultation of Stars): data...

Atmos. Chem. Phys., 10, 10473-10488, 2010
https://doi.org/10.5194/acp-10-10473-2010
© Author(s) 2010. This work is distributed under
the Creative Commons Attribution 3.0 License.

  08 Nov 2010

08 Nov 2010

GOMOS ozone profile validation using ground-based and balloon sonde measurements

J. A. E. van Gijsel1, D. P. J. Swart1, J.-L. Baray2, H. Bencherif2, H. Claude3, T. Fehr4, S. Godin-Beekmann5, G. H. Hansen6, P. Keckhut7, T. Leblanc8, I. S. McDermid8, Y. J. Meijer4, H. Nakane9, E. J. Quel10, K. Stebel6, W. Steinbrecht3, K. B. Strawbridge11, B. I. Tatarov12, and E. A. Wolfram10 J. A. E. van Gijsel et al.
  • 1National institute for public health and the environment (RIVM), Centre for environmental monitoring, Bilthoven, The Netherlands
  • 2University of La Réunion, Saint Denis, France
  • 3German weather service (DWD), Hohenpeissenberg, Germany
  • 4European space agency (ESA-ESRIN), Frascati, Italy
  • 5CNRS/UPMC/UVSQ, Paris, France
  • 6Norwegian air research institute (NILU), Tromsø, Norway
  • 7Laboratoire atmosphères, milieux, observations spatiales (LATMOS), Verrières-le-Buisson, France
  • 8Jet Propulsion Laboratory, California Institute of Technology, Table Mountain Facility, Wrightwood, USA
  • 9National institute for environmental studies, Asian environment research group, Tsukuba, Japan
  • 10Laser and applications research centre (CEILAP), CITEFA-CONICET, Villa Martelli, Argentina
  • 11Science and technology branch, Environment Canada, Centre for atmospheric research experiments, Egbert, Canada
  • 12National Institute for Environmental Studies, Atmospheric remote sensing section, Tsukuba, Japan

Abstract. The validation of ozone profiles retrieved by satellite instruments through comparison with data from ground-based instruments is important to monitor the evolution of the satellite instrument, to assist algorithm development and to allow multi-mission trend analyses.

In this study we compare ozone profiles derived from GOMOS night-time observations with measurements from lidar, microwave radiometer and balloon sonde. Collocated pairs are analysed for dependence on several geophysical and instrument observational parameters. Validation results are presented for the operational ESA level 2 data (GOMOS version 5.00) obtained during nearly seven years of observations and a comparison using a smaller dataset from the previous processor (version 4.02) is also included.

The profiles obtained from dark limb measurements (solar zenith angle >107°) when the provided processing flag is properly considered match the ground-based measurements within ±2 percent over the altitude range 20 to 40 km. Outside this range, the pairs start to deviate more and there is a latitudinal dependence: in the polar region where there is a higher amount of straylight contamination, differences start to occur lower in the mesosphere than in the tropics, whereas for the lower part of the stratosphere the opposite happens: the profiles in the tropics reach less far down as the signal reduces faster because of the higher altitude at which the maximum ozone concentration is found compared to the mid and polar latitudes. Also the bias is shifting from mostly negative in the polar region to more positive in the tropics

Profiles measured under "twilight" conditions are often matching the ground-based measurements very well, but care has to be taken in all cases when dealing with "straylight" contaminated profiles.

For the selection criteria applied here (data within 800 km, 3 degrees in equivalent latitude, 20 h (5 h above 50 km) and a relative ozone error in the GOMOS data of 20% or less), no dependence was found on stellar magnitude, star temperature, nor the azimuth angle of the line of sight. No evidence of a temporal trend was seen either in the bias or frequency of outliers, but a comparison applying less strict data selection criteria might show differently.

Download & links
Publications Copernicus
Special issue
Download
Citation
Share