Articles | Volume 15, issue 2
https://doi.org/10.5194/acp-15-667-2015
https://doi.org/10.5194/acp-15-667-2015
Research article
 | 
19 Jan 2015
Research article |  | 19 Jan 2015

Validation of OMI total ozone retrievals from the SAO ozone profile algorithm and three operational algorithms with Brewer measurements

J. Bak, X. Liu, J. H. Kim, K. Chance, and D. P. Haffner

Abstract. The accuracy of total ozone computed from the Smithsonian Astrophysical Observatory (SAO) optimal estimation (OE) ozone profile algorithm (SOE) applied to the Ozone Monitoring Instrument (OMI) is assessed through comparisons with ground-based Brewer spectrometer measurements from 2005 to 2008. We also compare the three OMI operational ozone products, derived from the NASA Total Ozone Mapping Spectrometer (TOMS) algorithm, the KNMI (Royal Netherlands Meteorological Institute) differential optical absorption spectroscopy (DOAS) algorithm, and KNMI's Optimal Estimation (KOE) algorithm. The best agreement is observed between SAO and Brewer, with a mean difference of within 1% at most individual stations. The KNMI OE algorithm systematically overestimates Brewer total ozone by 2% at low and mid-latitudes and 5% at high latitudes while the TOMS and DOAS algorithms underestimate it by ~1.65% on average. Standard deviations of ~1.8% are calculated for both SOE and TOMS, but DOAS and KOE have higher values of 2.2% and 2.6%, respectively. The stability of the SOE algorithm is found to have insignificant dependence on viewing geometry, cloud parameters, or total ozone column. In comparison, the KOE–Brewer differences are significantly correlated with solar and viewing zenith angles and show significant deviations depending on cloud parameters and total ozone amount. The TOMS algorithm exhibits similar stability to SOE with respect to viewing geometry and total column ozone, but has stronger cloud parameter dependence. The dependence of DOAS on observational geometry and geophysical conditions is marginal compared to KOE, but is distinct compared to the SOE and TOMS algorithms. Comparisons of all four OMI products with Brewer show no apparent long-term drift, but seasonal features are evident, especially for KOE and TOMS. The substantial differences in the KOE vs. SOE algorithm performance cannot be sufficiently explained by the use of soft calibration (in SOE) and the use of different a priori error covariance matrices; however, other algorithm details cause fitting residuals larger by a factor of 2–3 for KOE.

Download
Altmetrics
Final-revised paper
Preprint